Technical Specifications
| Part Description |
2H/JC25H-5P+25019-5P公壳+UL2464#26-5C灰色 L=350MM |
| Customer Part No. |
R30073467 |
| Drawing No. |
S007220288 |
| Version |
A |
| Date |
2019-08-13 |
Dimensions
| Item | Value |
|---|
| Total harness length | 350±10 mm |
| Heat-shrink setback from end | 5±2 mm |
| Cut wire length | 365 mm |
Terminal Definition
| Connector | Pins | Wiring |
|---|
| H1 (2509H-5P JC25 receptacle) | 5P | 1Red 2Yellow 3Green 4Black 5White |
| H2 (25019-05P-0B2 receptacle, white) | 5P | 1Red 2Yellow 3Green 4Black 5White |
Bill of Materials
| No. | Material Specification | Qty | Unit |
|---|
| 1 | 2509H-5P (JC25 receptacle) | 1 | PCS |
| 2 | 2509T tinned (JC25 terminal) | 5 | PCS |
| 3 | UL2464#26-5C shielded tinned copper, OD4.8mm, gray jacket | 365 | mm |
| 4 | 25019-05P-0B2 receptacle, white, Pitch:2.5mm | 1 | PCS |
| 5 | 25019-PT-2T2 tinned female terminal | 5 | PCS |
| 6 | Heat-shrink tube Φ5.0, black, L=25mm | 2 | PCS |
Process Requirements
1. Strip outer jacket 25±3mm and inner wires 2.5±0.5mm at both ends, crimp terminals and insert into housings as shown; 2. Terminal pull-out force >2.2Kg/F; 3. Cut braid and foil at the jacket-stripping edge without damaging inner wires, then sleeve and shrink the heat-shrink tube.
Test Conditions
100% tested and dot-marked on finished units: insulation resistance 20MΩ, DC high voltage 300V, continuity resistance 3Ω.
Packaging
50 PCS per bundle.
Introduction
Uses UL2464#26-5C shielded tinned-copper cable (OD4.8mm, gray jacket); one end is a 2509H-5P (JC25 receptacle), the other a white 25019-05P-0B2 receptacle (Pitch:2.5mm); 5 cores red/yellow/green/black/white straight-through, total length 350±10mm.
Features
- Shielded cable; braid and foil trimmed at the jacket edge and heat-shrunk at both ends
- 100% electrical test: insulation 20MΩ, DC hipot 300V, continuity 3Ω; 50 PCS/bundle
Custom Service
Custom wire harnesses are manufactured to your drawing: connector, wire gauge, length and color can be tailored.