Acquisition and High-Voltage Connection Wire Harness Project for Energy Storage Cabinet (ESS)
Project Background
Inside the Energy Storage System cabinet coexist high-voltage high-current circuits and safety signal circuits such as battery acquisition and fire alarm, laid within one enclosure, placing high demands on insulation, zoning and signal reliability. The high-voltage distribution link bears on system safety, while acquisition and alarm signals bear on operation monitoring.
The customer is an energy storage equipment manufacturer needing two harness solutions: high-voltage connection and in-cabinet acquisition/alarm.
Customer Requirements
The customer requires high-voltage circuits insulated and marked per safety rules, acquisition and alarm circuits kept away from power circuits with reliable connection, and clear, maintainable in-cabinet routing.
Solution and Design/Process Highlights
The engineering team selected cables and terminals by current carrying and temperature rise for the high-current links inside the high-voltage distribution box and at its output ends; high-voltage circuits get a prominent identification color and insulation protection. Battery acquisition and fire alarm signals use low-smoke halogen-free wires, routed away from high-voltage power circuits, with shielding on required loops. During sampling the team supported joint debugging of high-voltage circuits and safety signals before freezing drawings.
Product Scope and Testing
Products cover the high-voltage distribution box connection harness, acquisition and alarm signal harness, etc. Finished high-voltage circuits are tested for continuity, insulation and withstand voltage; signal circuits are checked point by point; wire numbers and polarity confirmed wire by wire.
Project Results
The harness was stably delivered in batches per ESS electrical drawings, with high-voltage and safety-signal circuits clearly zoned, supporting the customer's system joint debugging.
FAQ
Q: How are high-voltage and signal harnesses zoned inside the ESS cabinet?
A: High-voltage power circuits are routed separately and marked per current and insulation requirements; acquisition and alarm circuits are kept away from power circuits, shielded when needed, to reduce mutual influence.
Q: What are the material considerations for safety-related signal harnesses?
A: Alarm and acquisition loops use low-smoke halogen-free wires, with reliable connection and point-by-point check, meeting in-cabinet safety and environmental requirements.
Q: How is a new project arranged, from contact to sampling?
A: After the customer provides the system's electrical or structural drawings, the engineering team evaluates the solution and process route; samples and verification milestones proceed per the project plan and customer confirmation.
Contact Us
To learn about Energy Storage System harnesses, internal harnesses for industrial equipment or other customized harness solutions, please provide drawings or whole-unit structure information; the engineering team will reply with the solution and sampling schedule after evaluation. Email sz136138@szfandouai.cn, Tel 18929363263 (WhatsApp +86 18929363263). We are located at Unit 2, 7th Floor, Building E1-1, Qunyi Intelligent Manufacturing Industrial Park, No. 3 Xingyuan South Road, Zhongkai High-tech Zone, Huizhou City, Guangdong Province, China.