Analysis of Internal Connection Solutions for Conference Integrated
The Conference Integrated integrates, within a limited body, HD display, multi-touch, camera and microphone, OPS expansion and audiovisual interfaces; the internal harness must simultaneously transmit multiple signals and supply power. This article analyzes the general design ideas behind its internal connections.
1. Signal Classification and Zoning
1. Display signals: image signals from panel to main board commonly use FFC/FPC flat cable, laid thin against the panel.
2. Touch and peripheral signals: low-speed signals such as the touch board and USB/Type-C interfaces connect to the main board, with branches output per interface position.
3. Audio branches: speaker connection wires split left and right channels, routed along the housing edge with bending allowance.
2. High Integration and Cost Reduction
Integrating multiple signals into neat branches along the unit's routing and reasonably merging connectors can reduce line-side insertion points and lower assembly workload. High-speed and low-speed signals are routed separately, and interference-sensitive loops are shielded.
3. Material Selection and Connection
1. High-speed branches may choose coaxial cable or FFC by signal type to control signal integrity.
2. Connectors balance insertion feel and latch reliability, with board-end interfaces foolproof and reverse-insertion proof.
3. Power and signal branches are bundled separately, with positive and negative poles color-coded.
4. Testing and Verification
Finished products undergo wire-by-wire continuity testing; display and signal circuits are sampled by function; polarity and wire sequence are checked wire by wire, supporting the unit in verifying display, touch and audio functions.
This article is written by the engineering team of a professional wire harness manufacturer; for Conference Integrated or commercial display harness design needs, please contact us for technical support.