JST PUD Terminal SPUD-001T-P0.5|2.0mm Double Row 26–22AWG Crimp Terminal
Technical Specifications
Part Description SPUD-001T-P0.5
Customer Part No. Per drawing / BOM
Drawing No. Per drawing / BOM
Version Individual model page
Date —

Dimensions

ItemValue
Pitch2.0 mm
Circuits8–30P
RowsDual row
Wire RangeAWG26–22

Product Introduction

The SPUD-001T-P0.5 is a JST PUD series 2.0mm pitch, double-row crimp terminal, suitable for AWG26–22, conductor cross-section 0.13–0.33mm², and insulated wire diameter 0.95–1.5mm. After crimping, the terminals are housed in a PUDP housing and then mated with the B/S series PUDSS board pin header. PUD features a double-row, low insertion force, and secure locking structure, making it suitable for stable connections under conditions of vibration, clamping, and dry circuits. This page is organized by specific terminal part numbers to facilitate harness processing and BOM verification.

Structure and Matching

The terminal consists of a crimp area, box-shaped contact area, and anti-deformation structure. The contacts are made of copper alloy, tin-plated, and reflow-treated. The crimp area covers the conductor and insulation, and once inserted into the housing, it is fixed by the housing latch. The PUD housing has a safety latch, and the pin header has an anti-mismating key; terminals are only compatible with PUDP housings and PUDSS pin headers and cannot be mixed with PHD or PA series even if the pitch is the same 2.0mm. The difference between SPUD-001T and SPUD-002T mainly lies in the applicable wire gauge and insulation diameter range.

Selection Parameters

The table below is organized according to the public catalog and drawings. Specific plating, pin positions, color, packaging, and compatible wire gauge should be based on the part number specification sheet, drawings, or samples.

ItemParameter/Description
SeriesJST PUD
Nominal Pitch2.0 mm
Number of RowsDouble Row
Specific Part NumberSPUD-001T-P0.5
Applicable Wire GaugeAWG26–22
Conductor Cross-Section0.13–0.33 mm²
Insulation Outer Diameter0.95–1.5 mm
Rated Current3 A AC/DC (AWG22)
Rated Voltage250 V AC/DC
Operating Temperature-25~85℃
Contact ResistanceInitial 10 mΩ max; 20 mΩ max after environmental tests
Insulation Resistance1,000 MΩ min
Withstand Voltage800 V AC / minute
Terminal Material/PlatingCopper Alloy, Tin Plated (Reflow Process)
Packaging8,000 pcs/reel (public catalog)

Same Series Part Numbers and Compatibility

The following part numbers are used for retrieval, matching verification, and inquiry communication, and do not represent the full supply scope.

Part NumberDescriptionCompatibility / Use
SPUD-001T-P0.5PUD terminal, AWG26–22, insulation outer diameter 0.95–1.5mmPUDP housing / PUDSS pin socket
SPUD-002T-P0.5PUD terminal, AWG28–24, insulation outer diameter 0.76–1.5mmPUDP housing / PUDSS pin socket
PUDP-08V-S8P dual-row housing, natural colorB08B-PUDSS / S08B-PUDSS-1
B08B-PUDSS8P top-entry through-hole pin socket, without protrusionPUDP-08V-S
B08B-PUDSS-18P top-entry through-hole pin socket, with protrusionPUDP-08V-S
S08B-PUDSS-18P side-entry through-hole pin socket, with protrusionPUDP-08V-S

Application Scenarios

Typical scenarios suitable for board-to-wire connections in home appliance control boards, display devices, and industrial control boards include:

  • Board-to-board connections for home appliance control boards, display devices, and industrial control boards
  • Internal wiring harnesses requiring double-row 2.0mm high-density wiring
  • Connection points subject to vibration, pinching, or dry circuit conditions

Inquiry and Substitution

For inquiries, please provide the terminal part number, wire gauge, insulation outer diameter, plating, reel quantity, and delivery time; for substitutions, check the crimping range, contact plating, housing latch, and compatibility with PUDSS headers, and do not directly replace with the same 2.0mm pitch.

Related links: PUD Series Page; PUD Terminals Page; PUD Housings Page; PUD Headers Page; JST Agency Section; Agency Part Number Index; Terminal, Housing, and Header Selection Guide.

Get a Quote Back to List