Shuntai UL4389 Teflon Silicone Multi-core Wire
Technical Specifications
Part Description Shuntai UL4389 (per spec sheet)
Customer Part No. Per drawing / BOM
Drawing No. Per part number
Version Series overview
Date —

Dimensions

ItemValue
UL StyleUL4389
InsulationFEP (PTFE)
ConstructionMulti-core wire
ShieldingUnshielded
JacketSilicone rubber outer wrap
PitchN/A
Core count / AWGCore count and AWG per spec sheet
ColorsPer order

Product Introduction

This multi-core wire uses FEP Teflon as the core wire insulation, with an additional silicone outer layer, offering good flexibility in multi-core combinations. This part number belongs to the Shuntai composite multi-core wire series, mainly used for sensor lead wires and multi-circuit connections inside equipment. The number of cores and arrangement are confirmed according to the drawings. The page number is for structural indexing only; specific parameters are subject to the specification and sample.

Structure and Specifications

The cable harness is composed of multiple FEP insulated core wires with silicone outer covering. The core wires are neatly arranged, and the outer covering provides bundled protection. The following items can be preliminarily checked; the number of cores, conductor specifications, and color should be confirmed according to the specification and order.

  • UL Style: UL4389 (Structural Index)
  • Core Wire Insulation: FEP Teflon
  • Outer Covering: Silicone
  • Structure Type: Multi-core wire
  • Shielding: Unshielded
  • Number of Cores: Confirmed according to drawings
  • Color: Confirmed according to order

Selection Parameters

During the selection stage, please provide the equipment circuits, wiring length, and connection forms at both ends. Verify the number of cores, wire gauge, outer covering color, lead-out length, and branch positions. Sensor lead wires need attention to core sequence and signal correspondence; each core's purpose should be marked in the drawings.

ProjectExplanation
Number of Cores and Wire GaugeSelected according to circuit list
Outer Covering ColorConfirmed according to order
Length and BranchingProcessed according to drawings
TerminalsTerminals and connectors selected according to drawings

Application Scenarios

This wire is commonly used for sensor lead-outs, multi-circuit connections inside instruments, and bundled wiring inside equipment, suitable for locations requiring concentrated multi-core layout; the flexible multi-core structure facilitates bending and fixing during assembly.

  • Sensor lead wires and signal harnesses
  • Multi-circuit connections inside instruments
  • Bundled wiring inside equipment
  • Small electromechanical lead connection wires

Part Number Composition and Purchase Verification

This page of Shuntai UL4389 Teflon Silicone Multi-core Wire is used for series-level selection. After confirming the UL style and wire structure, the specific part number, wire gauge, conductor structure, insulation or jacket, and termination processing must be aligned item by item before proceeding to inquiry or sample verification; the series page cannot replace the specific part number page.

Verification ItemThis Page Standard
Series and StructureShuntai UL4389 Teflon Silicone Multi-core Wire; UL style, conductor structure, and wire structure are confirmed according to the part number
Component CompositionConductor, insulation, and if necessary, including jacket, shielding, or cable structure; verify according to the same part number and structure
Processing and TerminationCutting, stripping, crimping, soldering, heat shrink tubing, or terminal attachment confirmed according to drawings
Number of Cores and Wire Exit DirectionVerify according to part number, number of cores, color, pitch, and termination method, not based on general specifications
Conductor and Wire GaugeAWG, number of conductor strands, single strand diameter, and conductor resistance confirmed according to the specification and actual measurement
Insulation, Jacket, and PackagingMaterial, temperature rating, color, markings, length, and packaging confirmed according to the specific part number
Substitution BoundaryDifferent UL styles, wire gauges, conductor structures, insulation materials, and temperature ratings cannot be substituted based solely on outer diameter; ribbon cables also need to be checked for pitch, number of cores, color, and termination method.

When requesting a quote, it is recommended to provide: UL style, AWG, conductor structure, number of cores and pitch, insulation or jacket material, temperature rating, color and markings, cut length, termination method, estimated quantity, and delivery time. If any of these items are missing, verify according to the drawings or samples first to avoid substitution based solely on outer diameter.

Inquiry and Alternatives

Quotes are calculated based on part number, number of cores, quantity, and delivery time; substitute part numbers need to be confirmed against core wire material, outer insulation, number of cores, and terminals. It is recommended to provide drawings or samples. The sample parts should be checked for core sequence and appearance before mass supply; discounts, payment methods, etc., are executed according to the contract.

Related sections and similar materials: Shuntai Wires and Ribbon Cables Classification; Shuntai Wire Agency Section; Shuntai UL4602 Teflon Silicone Multi-core Wire; Shuntai FEP Teflon Multi-core Color Ribbon Cable.

Get a Quote Back to List